Pencatat data nirkabel multiparameter seri HOBO MX800 bekerja dengan sensor yang dapat diganti untuk menyediakan solusi yang sangat mudah dikonfigurasi untuk memantau konduktivitas/salinitas air, suhu, kedalaman, dan oksigen terlarut. Tersedia dalam model yang mudah dipasang dan sepenuhnya dapat direndam (MX801) dan model pembacaan langsung (MX802) untuk pengunduhan data yang mudah tanpa perlu mengeluarkan sensor dari air.
| Specification | Details |
|---|---|
| MX801 & MX802 – General Specifications | |
| Operating Range | -40° to 50°C (-40° to 122°F); cannot be frozen in ice |
| Radio Power | 1 mW (0 dBm) |
| Transmission Range | Approximately 30.5 m (100 ft), line-of-sight |
| Wireless Data Standard | Bluetooth 5 |
| Number of Supported Sensors | Up to 2 sensors |
| Maximum Cable Length | 120 m (400 ft) |
| Logging Rate | 5 seconds to 18 hours |
| Logging Modes | Fixed interval (normal or statistics), burst, or multiple intervals (up to 8 user-defined intervals with pause and repeat options) |
| Start Modes | Immediate, next interval, or date & time |
| Stop Modes | Memory full, never stop (overwrite oldest data), date & time, or after set logging period |
| Water Detect | Events logged when submerged or removed from water (MX801 only) |
| Time Accuracy | ±1 minute per month (0° to 50°C / 32° to 122°F) |
| Power | |
| Battery Type | Four AA, 1.5 V lithium batteries (user replaceable) |
| Battery Life | With W-CTD or W-CT sensors: 2 years (1-minute logging interval or slower) With W-DO sensor: 1 year (5-minute logging interval or slower) Faster logging, burst mode, excessive readouts, or continuous app connection will reduce battery life. |
| Memory & Data Transfer | |
| Memory Capacity | 730,000 measurements (4 MB), divided between channels |
| Data Download Time (Bluetooth 5+) | Full memory: ~3.5 minutes 120,000 measurements: ~1 minute Download time may increase with distance from logger. |
| Barometric Pressure (MX802 Only) | |
| Measurement & Calibrated Range | 66 to 107 kPa (9.6 to 15.5 psia), -20° to 50°C (-4° to 122°F) |
| Accuracy | Typical error: ±0.2 kPa (0.029 psi) Maximum error: ±0.5 kPa (0.073 psi) |
| Resolution | <0.01 kPa (0.0015 psi) |
| Pressure Response Time | <1 second to 90% at stable temperature |
| Contribution to Water Level Accuracy | Typical error: ±0.075% FS (0.3 cm / 0.01 ft water) Maximum error: ±0.15% FS (0.6 cm / 0.02 ft water) |
| Physical Specifications | |
| Logger Diameter | 4.14 cm (1.63 in.) |
| Length (Without Sensor) | 20 cm (8 in.) |
| Length with W-CTD Sensor | 36 cm (14 in.) |
| Length with W-CT Sensor | 33 cm (13 in.) |
| Mounting Loop | 12.7 × 22.6 mm (0.5 × 0.89 in.) |
| Weight | MX801 (Logger Head Only): 224 g (7.90 oz) MX802 (Logger Head Only): 226 g (7.97 oz) |
| Materials & Environmental Rating | |
| Wetted Materials | Logger: PVC housing, polyester film label, PET connector end cap, EPDM & Buna-N O-rings, passivated 316 stainless steel hardware (saltwater rated); MX802 includes ePTFE vent Collar: HDPE with titanium screws Note: Logger should be mounted so no metal parts contact other metals. |
| Depth / Environmental Rating | MX801: IP68, waterproof to 100 m (with sensor(s) attached) MX802: IP67, NEMA 6, weatherproof (not waterproof) |