HOBO Plug Load Data Logger

Overview

Data logger berakurasi tinggi dan mudah dipasang yang dirancang untuk mengukur serta merekam konsumsi daya dan energi pada beban colokan 120V. Perangkat ini cukup digunakan dengan mencolokkan peralatan kantor, mesin penjual otomatis (vending machine), atau perangkat listrik lainnya langsung ke data logger.

Features

  • Akurasi pengukuran 0,5%

  • Mode Meter untuk pemantauan real-time

  • Data bertanda waktu dan terakumulasi

  • Kapasitas memori besar

  • Backup baterai internal

  • Layar LCD lengkap dan informatif

  • Kompatibel dengan HOBOware & HOBOware Pro

Specifications

Note: The UX120-018 logger is intended for use on 15 AMP circuits (NEMA 5-15P) with a working voltage of 120V AC ±10% at 50/60Hz and a max power of 1800W.

  • Indoor use only
  • Insulation category 2

Maximum Current: 15 Amp

RMS Voltage Accuracy ±0.5% up to 14 A continuous;
±1.0% over 14 A at 100% duty cycle
RMS Current Accuracy ±0.5% up to 14 A continuous;
±1.0% over 14 A at 100% duty cycle
Active Power Accuracy ±0.5% up to 14 A continuous;
±1.0% over 14 A at 100% duty cycle
Active Energy Accuracy ±0.5% up to 14 A continuous;
±1.0% over 14 A at 100% duty cycle
Power Factor Accuracy ±0.02
Drift Up to 0.5% typical within 1 year
Resolution Voltage (RMS): 10 mV
Amps (RMS): 0.1 mA
Active Power: 10mW down to 1 watt loads @ 120VAC
Active Energy: 10 mW
Apparent Power: 10 mVA
Power Factor: 0.01 PF
Operating Environment Logging: 5°C to 40°C (41°F to 104°F)
Humidity: 0–95% RH (non-condensing)
Altitude: up to 2,000 m (6,562 ft)
Operating Modes Meter or logging when launched with HOBOware
Logging Rate 1 second to 18 hours, 12 minutes, 15 seconds
Statistics Sampling Rate 60 Hz or 16.67 ms (single-cycle)
Memory Modes Wrap when full or stop when full
Start Modes Immediate, push button, date & time, or next interval
Stop Modes When memory full, push button, or date & time
Restart Mode Push button
Time Accuracy ±1 minute per month at 25°C (77°F), see Plot A
Power Source Line-powered with 0.92 m (3 ft) AC power cord
or two AAA 1.5 V alkaline batteries (user replaceable)
Battery Life 2 years with line power
6 months battery only (no line power) with logging rate of 1 minute or greater operating at 25°C (77°F)
Memory Capacity 4 MB (1.4 million measurements, maximum)
Download Type USB 2.0 interface
Full Memory Download Time Approximately 1.5 minutes
LCD LCD is visible from 0° to 50°C (32° to 122°F); the LCD may react slowly or go blank in temperatures outside this range
Size 13.97 × 7.62 × 4.75 cm (5.5 × 3 × 1.87 in)
Weight 230.8 g (8.14 oz)
Ratings IP50

UL LogoUL Listed; UL Listed to Canadian safety standards

Calibration This device has been calibrated using equipment that has been tested in accordance with ANSI C12.20 0.5%.
Plot A Time Accuracy