Sensor suhu/kelembapan duct (Model HTY78_5 series) adalah sensor dengan presisi dan keandalan tinggi yang menggunakan resistance temperature detector (Pt100) sebagai sensor suhu dan polymer capacitive humidity detector (FP5)* sebagai sensor kelembapan.
Dengan rentang pengukuran yang luas dan stabilitas yang sangat baik, sensor ini dapat digunakan untuk berbagai aplikasi industri seperti pengukuran udara luar, serta digunakan pada duct, chamber, dan sebagainya pada bangunan umum untuk sistem tata udara.
| Item | Specification |
|---|---|
| Measuring range | |
| Temperature | -20 °C to 60 °C |
| Humidity | 0 to 100 %RH (non-condensing) |
| Measuring Accuracy | |
| Temperature | RTD (Pt100, 3-wire): ±0.3 °C |
| Voltage/current output: ±0.3 °C (at 15–35 °C) ±0.4 °C (at 0–50 °C) ±0.5 °C (at -20–60 °C) |
|
| Humidity | ±3 % RH (at 30–70 % RH, -20–5 °C) ±3 % RH (at 10–90 % RH, 5–60 °C) ±5 % RH (at 0–100 % RH, -20–60 °C) |
| Output Signal | |
| Temperature | RTD (Pt100, 3-wire): 100 Ω / 0°C, RTD (Pt100), conforming to JIS C 1604 Class A, 3-wire |
| Voltage output (1-5 V): 1-5 V DC (linear characteristic for 0-50 °C), 10 ΚΩ or more input impedance of the controller in connection |
|
| Current output (4-20 mA): 4-20 mA DC (linear characteristic for -20-60 °C), 500 2 or less input impedance of the controller in connection |
|
| Humidity | Voltage output (1-5 V): 1-5 V DC (linear characteristic for 0-100% RH), 10 k or more input impedance of the controller in connection |
| Current output (4-20 mA): 4-20 mA DC (linear characteristic for 0-100% RH), 500 Ω or less input impedance of the controller in connection |
|
| Time constant | |
| Temperature | 4 minutes or less (at air velocity: 2 m/s) |
| Humidity | 1 minutes or less (at air velocity: 2 m/s) |
| Power supply voltage | 24V AC (-15%-+10%) (frequency: 50/60 Hz ± 5%) 24 V DC±10% |
| Power consumption | For 24 V AC: voltage output 1.0 VA max., current output 2.0 VA max. For 24 V DC: voltage output 0.4 W max., current output 1.5 W max. |
| Insulation resistance | 500 V DC, 20 ΜΩ min. (between case and terminals) |
| Withstand voltage | When applying 500 V AC for 1 minute, leakage current 1 mA max. (between case and terminals) |
| Environmental Conditions | |
| Ambient temperature | Rated operating conditions & marginal operating conditions: – 20 – 60°C |
| Transportation/storage conditions: – 20 – 70°C | |
| Ambient humidity | Rated operating conditions & marginal operating conditions: 0-100% RH (without condensation) |
| Transportation/storage conditions: 5-95% RH (without condensation) (60°C Ctd or less) | |
| Vibration | Rated operating conditions & marginal operating conditions: 04.9m / (s ^ 2) (10-150 Hz) |
| Transportation/storage conditions:9.8m / (s ^ 2) (10-150 Hz) (should be in packed state) | |
| Air velocity | Rated operating conditions: 0.1 – 15m / s 0.5-15 m/s for Model HTY7815T4P00) |
| Marginal operating conditions: 0 – 15m / s | |
| Transportation/storage conditions: – | |
| Enclosure protection | |
| Housing | Dust-proof and splash-proof (IP54) The specified waterproof glands and specified multi-core cables, or the specified conduits must be used. |
| Major material, color | |
| Housing | Polycarbonate resin containing 20% of GF, gray (equivalent to DIC-651) |
| Cap | Polycarbonate resin, transparent |
| Weight | |
| Model 7803 | Approx. 240 g |
| Model 7813 | Approx. 210 g |
| Installation | Duct, AHU, Stevenson screen (with the dedicated bracket) |
| Wiring length | 100 m max. |
| Connection | Connections using the terminal blocks |
JIS: Japanese Industrial Standards