Fitur
- Dua prinsip operasi diadaptasi: induksi magnetik (ferrous) dan arus eddy (non-ferrous) untuk melakukan pengukuran non-destruktif
- 6 jenis probe tersedia untuk aplikasi yang berbeda
- Menampilkan dua mode kerja: DIRECT dan BATCH& dua cara pengukuran: CONTINUE dan SINGLE
- Statistik meliputi mean, maksimum, minimum, nomor tes dan standar deviasi.
- Memori 640 data
- Dua metode kalibrasi untuk koreksi yang lebih baik
- Terintegrasi dengan printer untuk mencetak nilai statistik jika diperlukan
- Indikasi baterai lemah dan alarm kesalahan
- Lampu latar untuk layar
- Shutdown otomatis atau manual
- Sesuai dengan standar DIN, ISO, ASTMBS.
| Standard Delivery | |
| Main unit | 1 |
| Probe | 1 |
| Substrate | 1 |
| Calibration foil | 1 |
| Charger | 1 |
| Printing paper | 1 |
| TIME certificate | 1 |
| Warranty card | 1 |
| Instruction manual | 1 |
Spesifikasi
| Probe types | F | N | |
| Measuring methods | magnetic induction | eddy current | |
| Measuring range | 0 ~1250 μm | 0 ~1250 μm, 0 to 40μm
(for chrome plate on copper) |
|
| Minimum resolution | 0.1μm | ||
| Tolerance | Zero point calibration | ±(3%H+1)μm | ± (3%H+1.5)μm |
| H means the thickness of tested piece | |||
| Two points calibration | ±[(1~3)%H+1]μm | ±[(1~3)%H+1.5]μm | |
| H means the thickness of tested piece | |||
| Measuring condition | Min. curvature radius (mm) | Convexity 1.5 | Convexity 3 |
| Min. testing area diameter (mm) | Ø7 | Ø5 | |
| Critical thickness of substrate(mm) | 0.5 | 0.3 | |
| Standards | DIN,ISO,ASTM,BS | ||
| Calibration | Zero and foil calibration | ||
| Interface | RS232 | ||
| Statistic | Number of measurement, mean, standarddeviation, maximum and minimum | ||
| Data memory | 640 readings | ||
| Limits | Adjustable with alarm | ||
| Power | NiMH rechargeable battery | ||
| Operating environment | Temperature: 0~40℃ | ||
| Humidity: 20%~90% | |||
| No strong magnetic field | |||
| Dimensions (mm) | 230×86×47 | ||
Optional Probes and Application Guide
| Probe model | F400 | F1 | F1/90º | F10 | N1 | CN02 | |
| Operating principle | Magnetic induction | Eddy current | |||||
| Measuring range (µm) | 0-400 | 0-1250 | 0-10000 | 0 to 1250 μm 0 to 40μm (for chrome plate on copper) |
10~200 | ||
| Low range resolution (µm) | 0.1 | 0.1 | 10 | 0.1 | 1 | ||
| Accuracy | One-point calibration (µm) | ±(3%H+1) | ±(3%H+10) | ±(3%H+1.5) | ±(3%H+1) | ||
| Two-point calibration (µm) | ±[(1~3)H%+0.7] | ±[(1~3)H%+1] | ±[(1~3)%H+10] | ±[(1~3)%H+1.5] | – | ||
| Measuring conditions | Min curvature of the min area (mm) | Convex 1 | 1.5 | Flatten | 10 | 3 | Flatten |
| Diameter of the min area (mm) | φ3 | φ7 | φ7 | φ40 | φ5 | φ7 | |
| Critical thickness of substrate (mm) | 0.2 | 0.5 | 0.5 | 2 | 0.3 | unlimited | |