| No. | project name | Specifications, parameters and indicators |
| 1 | Test force range ( N ) | 40 10000 _ |
| 2 | Test force indication accuracy | Above 4% of the maximum test force, the relative error of the indication value does not exceed ±1% , and the relative error of the indication value repeatability is not greater than 1% ; below 4% of the maximum test force , the indication value error does not exceed ±5N , and the indication value repeats Sexual error is not more than 5N . |
| 3 | The test force maintains the maximum allowable variation value | ±1%F N, 400N or less±5N |
| 4 | Friction measuring range (N) | 0~300 |
| 5 | Friction Indication Accuracy | In the range of 10N ~ 300N , the relative error of the indication value is not more than ±3% , and the relative error of the indication value repeatability is not more than 3% . |
| 6 | Spindle speed range (r/min) | 200 2000 |
| 7 | Spindle speed error ( r/min) | ±10 |
| 8 | Heater operating temperature range (℃) | Room temperature ~200 |
| 9 | Temperature control accuracy (℃) | ±2 |
| 10 | Time setting range (s or min) | 1 9999 |
| 11 | Number of revolutions setting range | 1 9999999 _ |
| 12 | Standard test steel ball diameter (mm) | φ12.7 |
| 13 | Dimensions of the testing machine (length × width × height) (mm) | 760×860×1600 |
| 14 | Testing machine net weight (kg) | about 650 |